Insulation Calculator

Find out how much insulation you need to reach a target R-value. Enter the area, the R-value you already have, the R-value you want, and the type of insulation. The calculator tells you how many inches to add and the total volume.

Your measurements

ft
ft
R
R
sq ft

Results

Depth to add10.9inches
R-value to add38 R
Area1,000 sq ft
Volume of insulation905 cu ft

Estimate only. Quantities are rounded up. Check product labels, your supplier and local building code before you buy or build.

How to use the insulation calculator

  1. Measure the length and width of the attic floor or wall area in feet.
  2. Estimate the R-value already in place (multiply existing depth by roughly R-3 per inch if unsure).
  3. Enter the target R-value from local code or energy guidance.
  4. Choose the insulation type. Add the coverage per bag from the bag chart to get a bag count.

Formula

R-value to add = target R − existing R

Depth to add (in) = R-value to add ÷ R-value per inch

Volume (cu ft) = area × depth ÷ 12. Bags = area ÷ coverage per bag at your target R-value.

Worked example

A 40 × 25 ft attic (1,000 sq ft) with R-11 in place and a target of R-49 needs R-38 more. With blown cellulose at about R-3.5 per inch, that is 10.9 inches of new insulation, or about 905 cubic feet.

Tips before you buy

  • R-value per inch differs between products. The figures here are typical; the bag or batt label is the final word.
  • Recommended attic levels depend on your climate zone. They commonly range from about R-38 to R-60; check local code.
  • Seal air leaks around lights, pipes and the attic hatch before adding insulation. It makes the insulation work much better.
  • Keep insulation away from recessed lights not rated for contact, chimneys and flues, and keep soffit vents clear.

Frequently asked questions

How many inches of insulation is R-49?

About 14 inches of blown cellulose (R-3.5 per inch) or about 19.6 inches of blown fiberglass (R-2.5 per inch).

How do I find my existing R-value?

Measure the depth of the insulation and multiply by roughly R-3 per inch for fiberglass batts or cellulose. Older, compressed insulation performs below its original rating.

How many bags of blown insulation do I need?

Use the coverage chart on the bag: it lists the square feet one bag covers at each R-value. Enter that figure in the optional field.

Can I put new insulation on top of old?

Usually yes, if the old insulation is dry and free of mold or pests. Do not cover it with a vapor barrier.

Last updated: